Is the “Match Quality” the only parameter to determine the accuracy of the results?
While match quality (MQ) is not the only parameter, it is perhaps the most important one to guide the engineer in finding the best solution. Proper dynamic testing always includes CAPWAP®, and most codes, standards and specifications require this “signal matching” procedure. The recommended CAPWAP® process is based on finding the lowest possible MQ, subject to constraints on several parameters (like damping and quakes among others).