How does debonding affect the TIP™ by “Probe Method”?
Engineers perform Thermal Integrity Profiling very early in the probe method process. Typically, they do so within the first couple days of concreting when debonding is unlikely. Thermal measurements do not require acoustic coupling, and like GGL, are insensitive to debonded access tubes.