Q

How does Thermal Integrity Profiling (TIP) determine concrete cover?

A

The total volume of concrete placed is used to determine a temperature to radius correlation (see Q 1093). The local radius is in direct ratio with the average temperature of the shaft in direct proportion to the local temperature to the average temperature. Subtracting the nominal cage radius from this local radius yields the effective local concrete cover.