Q

Can Thermal Integrity Profiling (TIP) be performed with water in the access tubes?

A

Only when using the thermal probe method for Thermal Integrity Profiling are access tubes necessary. The temperature sensors in the probes are infrared, and only work in air. As a result, the water must be removed from the access tubes. Nevertheless, the probes are completely waterproof to protect against inadvertent submersion.