{"version":"1.0","provider_name":"Pile Dynamics, Inc.","provider_url":"https:\/\/www.pile.com\/es\/","author_name":"benchmark","author_url":"https:\/\/www.pile.com\/es\/author\/benchmark\/","title":"How often should the calibration of the Pile Driving Analyzer\u00ae (PDA) be checked? - Pile Dynamics, Inc.","type":"rich","width":600,"height":338,"html":"<blockquote class=\"wp-embedded-content\" data-secret=\"wGUDznJCa3\"><a href=\"https:\/\/www.pile.com\/es\/resources\/faqs\/faq-often-calibration-pile-driving-analyzer-pda-checked\/\">How often should the calibration of the Pile Driving Analyzer\u00ae (PDA) be checked?<\/a><\/blockquote><iframe sandbox=\"allow-scripts\" security=\"restricted\" src=\"https:\/\/www.pile.com\/es\/resources\/faqs\/faq-often-calibration-pile-driving-analyzer-pda-checked\/embed\/#?secret=wGUDznJCa3\" width=\"600\" height=\"338\" title=\"\u00abHow often should the calibration of the Pile Driving Analyzer\u00ae (PDA) be checked?\u00bb \u2014 Pile Dynamics, Inc.\" data-secret=\"wGUDznJCa3\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\" class=\"wp-embedded-content\"><\/iframe><script>\n\/*! This file is auto-generated *\/\n!function(d,l){\"use strict\";l.querySelector&&d.addEventListener&&\"undefined\"!=typeof URL&&(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&&!\/[^a-zA-Z0-9]\/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret=\"'+t.secret+'\"]'),o=l.querySelectorAll('blockquote[data-secret=\"'+t.secret+'\"]'),c=new RegExp(\"^https?:$\",\"i\"),i=0;i<o.length;i++)o[i].style.display=\"none\";for(i=0;i<a.length;i++)s=a[i],e.source===s.contentWindow&&(s.removeAttribute(\"style\"),\"height\"===t.message?(1e3<(r=parseInt(t.value,10))?r=1e3:~~r<200&&(r=200),s.height=r):\"link\"===t.message&&(r=new URL(s.getAttribute(\"src\")),n=new URL(t.value),c.test(n.protocol))&&n.host===r.host&&l.activeElement===s&&(d.top.location.href=t.value))}},d.addEventListener(\"message\",d.wp.receiveEmbedMessage,!1),l.addEventListener(\"DOMContentLoaded\",function(){for(var e,t,s=l.querySelectorAll(\"iframe.wp-embedded-content\"),r=0;r<s.length;r++)(t=(e=s[r]).getAttribute(\"data-secret\"))||(t=Math.random().toString(36).substring(2,12),e.src+=\"#?secret=\"+t,e.setAttribute(\"data-secret\",t)),e.contentWindow.postMessage({message:\"ready\",secret:t},\"*\")},!1)))}(window,document);\n\/\/# sourceURL=https:\/\/www.pile.com\/wp-includes\/js\/wp-embed.min.js\n<\/script>\n","description":"The American Society for Testing and Materials (ASTM) Standard D4945 requires that an engineer check the PDA\u2019s internal calibration each testing day. Moreover, PDI recommends that an engineer records a Calibration Test (CT) signal before each test. Following, an engineer can replay the CT to confirm that the PDA.&#8217;s internal calibration was correct during testing...."}